Register | Log In
Welcome
Catalog
Shopping Cart
Checkout
My Account
Contact Us
 
Catalog > Murphy by Enovation Controls > Vibration - Time - Overspeed > Electronic Speed Switches > 


Cart Summary
• Your Cart is Empty
• View Cart
Search
Search
 
 
Navigation
• Catalog
• Murphy by Enovation Controls
• Pressure & Vacuum
• Temperature
• Level
• Vibration - Time - Overspeed
• Timers: Mechanical
• Tachometers: Analog & Digital
• Hourmeters
• Electronic Speed Switches
• OS77D-900NTO (20700127): Electronic Speed Switch
• OS77I-040NTO (20700124): Electronic Speed Switch
• SS300-12 (20700166): Electronic Speed Switch
• SS300-24 (20700167): Electronic Speed Switch
• SS300-LF-12 (20700168): Electronic Speed Switch
• SS300-LF-24 (20700169): Electronic Speed Switch
• HD9063 (20700117): Dual Set Point Speed Switch
• Magnetic Pickups
• Magnetic Switches & Tattletale® Annunciators
• Engine Panels
• Engine & Motor Controls
• Valves
• Electric Gages
• Gen Set Controls
• PowerView™ & MurphyLink™ Series
• PowerCore™ Controllers & Panels
• FW Murphy Production Controls
• Trombetta
• CRE Technology
• Blink Marine
• Johnson Matthey
• EGIS Mobile Electric
• ElectroDyne
• Beaumont Manufacturing and Distribution Company
• NGK Industrial Spark Plugs & Oxygen Sensors
• Denso
• SENS
• Hewitt Industries
• MurCal Products
• MurCal's Toolbox
• Clearance Sale


SS300-LF-24 (20700169): Electronic Speed Switch
20700169.jpg

SS300-LF-24: Electronic Speed Switch; distributor ignition; alternator; 24V (20700169)


The Murphy 24V with Low Frequency SS300-LF-24 is a single set point speed switch with SPDT relay dry contact output. The trip point is set by a potentiometer. An LED indicates when the signal source is present. A second LED turns on when the trip point is reached. An optional time delay is on board to delay operation of the relay for 2-6 seconds after the set point has been reached. The SS300-LF-24 is intended for installation within a weatherproof enclosure to protect it from rain, dust, etc.

Application: Overspeed shutdown. Shuts down the engine if RPM exceeds the pre-set limit. Speed sensitive pull-in/drop-out. Engage or disengage PTO’s, 4-wheel drives, other switch points, etc. according to speed of engine being monitored. The SS300-LF-24 can select between two pressure switch set points according to speed of the engine or transmission and thus give maximum protection to the equipment while at operating RPM and eliminate nuisance alarms when at idle.


Images

Larger View

 

Features:

  • Low frequency
  • Single set point
  • Magnetic Pickup
  • Compact design
  • Field adjustable set points
  • High noise immunity

Product Specifications:

  • Part No.: SS300-LF-24
  • Power Requirements: 24 VDC (18-30 VDC)
  • Frequency Signal: Minimum Input Voltage Signal: 4.5 Vrms
  • Maximum Input Voltage Signal: 50 Vrms
  • Maximum Current Pull In: 46 mA; Pickup only: 10.5 mA
  • Frequency Range in Hz: 25-2000
  • Reset Differential Alternator (Low Frequency): 2 Hz Differential
  • Output: Relay contact, SPDT, resistive load, 6 A, 30 VDC
  • Time Delay: When terminal 7 is grounded, the relay operation is delayed for 2-6 seconds after rpm set point is reached
  • Adjustment: 20–turn potentiometer(s)
  • Temperature Range: -4° to 185°F (-20° to 85°C)
  • Relative Humidity: 0 to 95% Non-condensing
  • Case: Black, ABS plastic
  • Shipping Weight: 0.24 lb. (108 g)
  • Shipping Dimensions: 8 x 4 x 4-1/2 in. (203 x 102 x 114 mm)



Literature

  1. Sales Bulletin
  2. Installation Instructions



MurCal is an Authorized Distributor of Enovation Controls products.
MurCal provides experienced application and product support, before and after the sale.

 

For California customers: Prop 65 WARNING: This product may have been manufactured with or uses components that can expose you to chemicals which are known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov.

Price: $219.99

 
 