Register | Log In
 


Cart Summary
Your Cart is Empty
View Cart
Search
 
 
Navigation
Catalog
Murphy
Pressure & Vacuum
Temperature
Level
Vibration - Time - Overspeed
Magnetic Switches & Tattletale® Annunciators
Engine Panels
Engine & Motor Controls
Compressor Controls
C3 Series: Centurion Configurable Controller
C277 Temperature Sensing Module (50701936)
C287 Analog Input/Output Module (50701944)
Dual Ignition Adapter (65700053)
RJ45 Patch Cable: 2' (00005293)
RJ45 Patch Cable: 4' (00004925)
RJ45 Patch Cable: 6' (00006896)
Adapter: RJ45 to DB9 (00007621)
Harness Kit: C267 (2') (00004924)
M2 Wireless™ Monitoring System
TTDJ Series Annunciators
Valves
Electric Gages
Gen Set Controls
PowerView™ & MurphyLink™ Series
Trombetta
Testo
Compliance Controls
Denso
SENS
Hewitt Industries
DynaGen Technologies
MurCal's Toolbox


C267 Standard Input/Output Module Rev. H (Z20761)
C267.use.(240).jpg The C267 communications module adds standard input/output capability to existing and future Ryeso controllers via MODBUS RTU communication using an RS-485 port.
The module can also be used with PLC’s manufactured by others and for gathering information from remote sensors. Rugged Design, Shunt Selectable Analog Types, UL/cUL Listed Class 1 Div. 2, Groups C & D.

Digital Inputs:
8 - optically isolated inputs. Each accepts either B+ or B- for activation.
Digital Inputs:
8 - optically isolated inputs. Each accepts either B+ or B- for activation.
Analog Inputs:
7 - each analog input is hardware selectable to read the following end devices: 4-20 mA, 0-5 VDC, and/or Electric Gauge Sending Units. These analog inputs can be configured independently.
1 - Battery Monitor
Frequency Inputs:
1 - Optically Isolated Frequency input requiring at least 2Vrms for activation. Used for speed reference.
Range: 60 - 10,000 Hz.
Outputs:
8 - FET Outputs consistent with use in Class 1 Division 2 Hazardous areas. Each output rated at 5 Amps. Total current draw through unit not to exceed 18 Amps when both PWR2 pins are connected.
Input Voltage:
9 to 28 VDC
Operating Temperature:
-22° to +158° F (-30° to +70° C)
Storage Temperature:
-22° to +158° F (-30° to +70° C)
Communications:
1 - RS-485 9600-N-8-1 Communication port. Connection is made via modular RJ45 jack. There are two jacks for simple connection to other Comm Series Modules. If more than one module is used, you can bring your patch cable into Port A and then connect from Port B to the next module. This can be repeated until your input/output resources are satisfied. The last module in line must have a terminating resistor installed in the second jack. A maximum of 32 devices can be hooked together.
Product Weight:
1.5 lb. (0.7 kg.)
Product Dimensions:
7.0”H x 1.5”W x 4.75”D (178 x 38 x 121 mm)
Shipping Weight:
2.2 lb. (1.0 kg.)
Shipping Dimensions:
12.0”H x 6.0”W x 6.0”D (304 x 152 x 152 mm)

Sales Bulletin
Price: $582.00

 
 
Tell a Friend


Customers Also Bought
MP3298(80).jpg
MP3298 Magnetic Pickup (20700162)
The MP3298 Magnetic Pickup
Price: $56.75
 
AT03069(80).jpg
AT03069 (40700249): Murphymatic® Engine Throttle Controller
The AT03069 Murphymatic® Engine Throttle Controller is a completely reliable heavy duty device developed specifically to automatically control engine speed to meet system demand.
Price: $479.00
 
C287(80).jpg
C287 Analog Input/Output Module (50701944)
The C287 module adds true current analog input and output capability to existing and future Murphy controllers via MODBUS RTU communications using an RS-485 port.
Price: $1,002.00